Impedance-based cell monitoring: barrier properties and beyond

In multicellular organisms epithelial and endothelial cells form selective permeable interfaces between tissue compartments of different chemical compositions. Tight junctions which connect adjacent cells, control the passage of molecules across the barrier and, in addition, facilitate active transp...

Verfasser: Benson, Kathrin
Cramer-Stoll, Sandra
Galla, Hans-Joachim
FB/Einrichtung:FB 12: Chemie und Pharmazie
FB 13: Biologie
Dokumenttypen:Artikel
Medientypen:Text
Erscheinungsdatum:2013
Publikation in MIAMI:11.03.2013
Datum der letzten Änderung:16.04.2019
Angaben zur Ausgabe:[Electronic ed.]
Quelle:Fluids and Barriers of the CNS 10 (2013) 5
Schlagwörter:Barrier forming cells; Endothelium; Epithelium; Blood–brain barrier; Electrical resistance; TEER; Impedance spectroscopy
Fachgebiet (DDC):540: Chemie
570: Biowissenschaften; Biologie
Lizenz:CC BY 3.0 DE
Sprache:English
Anmerkungen:Finanziert durch den Open-Access-Publikationsfonds 2012/2013 der Deutschen Forschungsgemeinschaft (DFG) und der Westfälischen Wilhelms-Universität Münster (WWU Münster).
Format:PDF-Dokument
URN:urn:nbn:de:hbz:6-97359432004
Weitere Identifikatoren:DOI: doi:10.1186/2045-8118-10-5
Permalink:https://nbn-resolving.de/urn:nbn:de:hbz:6-97359432004
Onlinezugriff:2045-8118-10-5.pdf
LEADER 04321cam a2200361uu 4500
001 cde751dc-2bd4-48e9-9303-f067bb4317e6
003 miami
005 20190416
007 c||||||||||||a|
008 130311e20130311||||||||||#s||||||||eng||||||
024 7 |a urn:nbn:de:hbz:6-97359432004  |2 urn 
024 7 |a doi:10.1186/2045-8118-10-5  |2 doi 
041 |a eng 
082 0 |a 540 Chemie  |2 23  |a 570 Biowissenschaften; Biologie  |2 23 
100 1 |a Benson, Kathrin  |u FB 12: Chemie und Pharmazie  |u FB 13: Biologie  |0 http://d-nb.info/gnd/1047403714  |4 aut 
110 2 |a Universitäts- und Landesbibliothek Münster  |0 http://d-nb.info/gnd/5091030-9  |4 own 
245 1 0 |a Impedance-based cell monitoring: barrier properties and beyond 
250 |a [Electronic ed.] 
264 1 |c 2013-01-10 
264 2 |b Universitäts- und Landesbibliothek Münster  |c 2013-03-11 
300 |a 11 S. 
500 |a Finanziert durch den Open-Access-Publikationsfonds 2012/2013 der Deutschen Forschungsgemeinschaft (DFG) und der Westfälischen Wilhelms-Universität Münster (WWU Münster). 
506 0 |a free access 
510 0 |a Fluids and Barriers of the CNS 10 (2013) 5 
520 3 |a <p>In multicellular organisms epithelial and endothelial cells form selective permeable interfaces between tissue compartments of different chemical compositions. Tight junctions which connect adjacent cells, control the passage of molecules across the barrier and, in addition, facilitate active transport processes. The cellular barriers are not static but can be deliberately modulated by exposure to specific external stimuli. In vitro models representing the essential absorption barriers of the body are nowadays available, thus allowing investigation of the parameters that control permeability as well as transport processes across those barriers. Independent of the origin of the barrier forming cells, techniques are needed to quantify their barrier integrity. One simple assay is to measure the permeability for given hydrophilic substrates possessing different molecular weights like sucrose or dextrans. However, this technique is time-consuming and labor-intensive. Moreover, radioactive or fluorescently-labeled substrates are needed to allow easy analytical detection. Finally, if transport processes are investigated, the standard permeant may interfere with the transport process under investigation or might even alter the barrier integrity by itself. Thus, independent, non-invasive techniques are needed to quantify the barrier integrity continuously during the experiment. Such techniques are available and are mainly based on the measurement of the transendothelial or transepithelial electrical resistance (TEER) of barrier forming cells grown on porous membranes. Simple devices using two sets of electrodes (so-called Voltohmeters) are widely used. In addition, an easy-to-use physical technique called impedance spectroscopy allows the continuous analysis of both the TEER and the electrical capacitance giving additional information about the barrier properties of cells grown on permeable membranes. This technique is useful as a quality control for barrier forming cells. Another impedance-based approach requires cells to be grown directly on solid, micro-structured electrodes. Here, we will discuss the physical background of the different techniques; advantages, disadvantages, and applications will be scrutinized. The aim is to give the reader a comprehensive understanding concerning the range and limits of the application, mainly focusing on endothelial cells.</p> 
540 |a CC BY 3.0 DE  |u http://creativecommons.org/licenses/by/3.0/de/ 
653 0 |a Barrier forming cells  |a Endothelium  |a Epithelium  |a Blood–brain barrier  |a Electrical resistance  |a TEER  |a Impedance spectroscopy 
655 7 |2 DRIVER Types  |a Artikel 
655 7 |2 DCMI Types  |a Text 
700 1 |a Cramer-Stoll, Sandra  |u FB 12: Chemie und Pharmazie  |u FB 13: Biologie  |0 http://d-nb.info/gnd/1019276096  |4 aut 
700 1 |a Galla, Hans-Joachim  |u FB 12: Chemie und Pharmazie  |0 http://d-nb.info/gnd/1145392083  |4 aut 
856 4 0 |3 Zum Volltext  |q text/html  |u https://nbn-resolving.de/urn:nbn:de:hbz:6-97359432004  |u urn:nbn:de:hbz:6-97359432004 
856 4 0 |3 Zum Volltext  |q application/pdf  |u https://repositorium.uni-muenster.de/document/miami/cde751dc-2bd4-48e9-9303-f067bb4317e6/2045-8118-10-5.pdf